1999 Chance Ah-28 Recalls

Recalls on record Updated July 2026

The 1999 Chance Ah-28 has 3 NHTSA recall campaigns affecting an estimated 634 vehicles. Recall repairs are always free at any authorized dealer. Last updated July 5, 2026.

Recall campaigns

POWER TRAIN 02V192000 2002-07-23 109 affected
Defect

ON CERTAIN STREETCARS (DIESEL AND CNG MODELS) AND RT-52 DIESEL COACHES MANUFACTURED WITH AT-545 AND MT643 TRANSMISSIONS WHICH USE A MANUAL TRANSMISSION CONTROL CABLE. THE TRANSMISSION CONTROL CABLE MAY RUB AGAINST THE JUNCTION BOX POWER STUD LOCATED ON THE BOTTOM OF THE JUNCTION BOX.

Consequence

LONG-TERM WEAR CAN ALLOW THE POWER STUD TO SHORT TO GROUND THROUGH THE TRANSMISSION CONTROL CABLE, RESULTING IN ELECTRICAL ARCING AND THE IGNITION OF COMBUSTIBLE MATERIALS IN THE JUNCTION BOX COMPARTMENT.

Remedy

DEALERS WILL INSPECT THE VEHICLE TO DETERMINE IF EITHER THE POWER STUD INSULATION BOOT AND/OR THE TRANSMISSION SHIFT CABLE CLAMP IS MISSING. BOTH THE INSULATION BOOT AND THE CLAMP WILL BE INSTALLED IF MISSING. OWNER NOTIFICATION IS EXPECTED TO BEGIN DURING JULY 2002. OWNERS WHO TAKE THEIR VEHICLES TO AN…

ELECTRICAL SYSTEM 01V013000 2001-01-15 330 affected
Defect

VEHICLE DESCRIPTION: STREETCARS. ABRASION TO INSULATION ON SOME POSITIVE POWER CABLES CAN RESULT IN THE GROUNDING OF THE POWER CABLE.

Consequence

THE ARCING AND HEAT GENERATED AS A RESULT OF THE GROUNDED CABLE CAN RESULT IN THE COMBUSTION OF INSULATION, PAINT, UNDER-COATING, AND OTHER CHASSIS COMPONENTS.

Remedy

OWNERS/OPERATORS WILL BE REQUESTED TO IMMEDIATELY INSPECT THEIR VEHICLES FOR POWER CABLE ABRASION DAMAGE AND REMOVE THE UNITS WITH VISIBLE CABLE DAMAGE FROM SERVICE. THEY WILL BE SHIPPED REPLACEMENT PARTS AND INSTRUCTIONS FOR REPAIR IMMEDIATELY. OWNER/OPERATORS WITH UNITS THAT HAVE NO VISIBLE CABLE DAMAGE WILL BE…

ELECTRICAL SYSTEM 99V196000 1999-07-22 195 affected
Defect

VEHICLE DESCRIPTION: STREETCARS AND TRANSIT COACHES . THE TRANSMISSION CONTROL CABLE CAN RUB AGAINST THE ELECTRICAL JUNCTION BOX POWER STUD ALLOWING BATTERY CURRENT TO FLOW DIRECTLY TO GROUND.

Consequence

ELECTRICAL ARCING CAN IGNITE COMBUSTIBLE MATERIALS IN THE JUNCTION BOX, INCREASING THE RISK OF PROPERTY DAMAGE AND PERSONAL INJURY.

Remedy

DEALERS WILL SECURE THE CABLE AWAY FROM THE JUNCTION BOX POWER STUD WITH A CLAMP THAT IS SECURED TO THE FLOOR BY A SCREW AND WASHER; AND THE JUNCTION BOX POWER STUD WILL BE INSULATED WITH A RUBBER BOOT.

Sources & methodology

Recall, complaint, and investigation records from official NHTSA datasets (FLAT_RCL, FLAT_CMPL, FLAT_INV), synced weekly. Counts reflect NHTSA records for the 1999 Chance Ah-28 as of July 5, 2026. Complaint narratives are consumer-submitted and unverified. This page contains ads and affiliate links. Full methodology.