2001 Utilimaster Walk-In Van Recalls

Recalls on record Updated July 2026

The 2001 Utilimaster Walk-In Van has 4 NHTSA recall campaigns affecting an estimated 23,515 vehicles. Recall repairs are always free at any authorized dealer. Last updated July 5, 2026.

Recall campaigns

SEAT BELTS 18V377000 2018-06-06 3,194 affected
Defect

Spartan Motors USA (Spartan) is recalling certain 1991-2018 Utilimaster Aeromaster and Walk-In Vans. These vehicles were manufactured with front seat belts that do not have an emergency locking seat belt retractor or automatic locking seat belt retractor. As such, these vehicles fail to comply with the requirements…

Consequence

Without retractors, the seat belts may not accommodate different size occupants, therefore the occupants may not be properly restrained in the event of a crash, increasing the risk of injury.

Remedy

Spartan will notify owners and will install seat belts with retractors, free of charge. The recall began on August 6, 2018. Owners may contact Spartan customer service at 1-800-582-3454. Spartan's number for this recall is 18019.

ELECTRICAL SYSTEM 03V275000 2003-07-29 4,001 affected
Defect

ON CERTAIN WALK-IN VANS, A FUSE WAS INSTALLED BY FORD. HOWEVER, UTILIMASTER INSTALLED A WIRE. THE FUSE IS NOT COMPATIBLE WITH THE WIRE GAUGE INSTALLED BY UTILIMASTER.

Consequence

SHOULD A FAILURE OCCUR IN A VEHICLE COMPONENT SUCH AS A FAN, HEATED MIRROR AND/OR OTHER IGNITION-HOT OPTION, THE INSULATION AROUND THE WIRING TO THE FAN COULD MELT.

Remedy

OWNERS WILL BE PROVIDED WITH A REPLACEMENT FUSE. OWNER NOTIFICATION BEGAN OCTONER 1, 2003. OWNERS SHOULD CONTACT UTILIMASTER AT 1-800-582-3454.

SERVICE BRAKES, HYDRAULIC 01V178000 2001-05-31 558 affected
Defect

VEHICLE DESCRIPTION: WALK-IN DELIVERY VANS SUPPLIED TO FED EX (FED EX W700). A BOLT AND NUT INSTALLED THROUGH THE CHASSIS FRAME RAIL TO SUPPORT A NEW SEAT MOUNT DESIGN COULD HAVE PARTIALLY COLLAPSE A BRAKE LINE AS THE NUT WAS TIGHTENED ON THE BOLT.

Consequence

IF UNDETECTED, THIS CONDITION COULD CAUSE PARTIAL OR TOTAL LOSS OF FUNCTION OF THE FRONT BRAKES OF THE VEHICLE.

Remedy

FED EX WILL BE SUPPLIED WITH INSTRUCTIONS FOR INSPECTING FOR THE DEFECT AND HOW TO REPLACE THE DEFECTIVE BRAKE LINE IF THE PROBLEM EXISTS. FED EX WAS NOTIFIED BY TELEPHONE ON MAY 25, 2001. ONLY FED EX VEHICLES ARE INVOLVED.

VISIBILITY 01V003000 2001-01-05 15,762 affected
Defect

VEHICLE DESCRIPTION: WALK-IN DELIVERY VANS SUPPLIED TO THE UNITED STATES POSTAL SERVICE. UNDER CERTAIN SNOW CONDITIONS, IF MOISTURE GETS INTO THE BLOWER MOTOR AND SUBSEQUENTLY REFREEZES, THE BLOWER MOTOR COULD SEIZE CAUSING A RESISTOR TO OVERHEAT.

Consequence

WHEN A RESISTOR OVERHEATS, THE PLENUM COULD MELT, RESULTING IN DEFORMATION AND POSSIBLE IGNITION.

Remedy

UTILIMASTER WILL INSTALL FUSES BETWEEN THE RESISTORS AND THE POWER SUPPLY, WHICH WILL PROTECT THE RESISTOR ASSEMBLY IN THE EVENT OF AN OVERCURRENT SITUATION. AN EXISTING FUSE WILL BE RESIZED TO PROTECT THE WIRING HARNESS IN HIGH-SPEED FAN OPERATION. OWNER NOTIFICATION BEGAN JANUARY 24, 2001. ONLY US POSTAL…

Sources & methodology

Recall, complaint, and investigation records from official NHTSA datasets (FLAT_RCL, FLAT_CMPL, FLAT_INV), synced weekly. Counts reflect NHTSA records for the 2001 Utilimaster Walk-In Van as of July 5, 2026. Complaint narratives are consumer-submitted and unverified. This page contains ads and affiliate links. Full methodology.