The 2002 Tiffin Zephyr has 3 NHTSA recall campaigns affecting an estimated 22,649 vehicles. Recall repairs are always free at any authorized dealer. Owners have filed 1 complaint with NHTSA, most often about the structure. Last updated July 5, 2026.
Recall campaigns
EQUIPMENT11V0820002011-02-0810,683 affected
Defect
TIFFIN MOTORHOMES IS RECALLING CERTAIN RECREATIONAL VEHICLES EQUIPPED WITH 1200-SERIES NORCOLD REFRIGERATORS. THE POPULATION OF REFRIGERATORS BEING ADDRESSED CONTAINS EITHER A SENSING ALGORITHM OR THERMAL SWITCH TO SHUT OFF POWER TO THE REFRIGERATOR WHEN HIGH TEMPERATURES ARE DETECTED IN ORDER TO PREVENT A POTENTIAL…
Consequence
THE SENSING ALGORITHM OR THERMAL SWITCH INSTALLED TO SHUT OFF POWER TO THE REFRIGERATOR WHEN HIGH TEMPERATURES ARE DETECTED DUE TO A POSSIBLE HYDROGEN GAS LEAK MAY NOT SHUT OFF IN SUFFICIENT TIME TO PREVENT A FIRE.
Remedy
TIFFIN MOTORHOMES IS WORKING WITH NORCOLD TO IDENTIFY AND NOTIFY ANY AFFECTED OWNERS. OWNERS WILL BE INSTRUCTED TO CONTACT NORCOLD DEALERS TO RECEIVE THE REMEDY FREE OF CHARGE. PLEASE SEE NORCOLD'S DEFECT REPORT 10E-049 FOR ADDITIONAL INFORMATION. THE SAFETY RECALL BEGAN ON FEBRUARY 17, 2011. OWNERS MAY CONTACT…
EQUIPMENT09V4430002009-11-17528 affected
Defect
TIFFIN IS RECALLING CERTAIN RECREATIONAL VEHICLE EQUIPPED WITH NORCOLD MODEL 1200LR AND 1200LRIM REFRIGERATORS, MANUFACTURED FROM DECEMBER 1, 2001, WITH SERIAL NUMBERS BETWEEN 1273701 AND 1536607, NON-CONSECUTIVELY. A FATIGUE FAILURE IN THE SECTION OF THE COOLING UNIT WHICH CONTAINS THE REFRIGERANT COULD ALLOW THE…
Consequence
IF A LEAK OCCURS AND THE UNIT IS CONTINUES TO OPERATE, HYDROGEN GAS MAY BE EXPELLED AND CAN BE IGNITED, RESULTING IN A FIRE, POSSIBLY CAUSING SERIOUS INJURY OR DEATH.
Remedy
TIFFIN IS WORKING WITH NORCOLD AND TIFFIN WILL NOTIFY OWNERS AND THE VEHICLE'S REFRIGERATOR WILL BE REPAIRED FREE OF CHARGE BY NORCOLD. PLEASE SEE NORCOLD'S DEFECT REPORT 09E-027. OWNERS MAY CONTACT NORCOLD'S RECALL CENTER AT 1-800-767-9101.
EQUIPMENT07V5170002007-11-0511,438 affected
Defect
ON CERTAIN MOTOR HOMES EQUIPPED WITH A TWO-DOOR REFRIGERATOR MANUFACTURED BY THE DOMETIC CORPORATION, THESE REFRIGERATORS MAY HAVE A DEFECT IN THE BOILER TUBE. PRESSURIZED COOLANT SOLUTION COULD BE RELEASED INTO AN AREA WHERE AN IGNITION SOURCE (GAS FLAME) IS PRESENT.
Consequence
RELEASE OF COOLANT UNDER CERTAIN CONDITIONS COULD IGNITE AND RESULT IN A FIRE.
Remedy
TIFFIN MOTORHOMES WILL BE WORKING WITH DOMETIC IN ORDER TO REPAIR THESE REFRIGERATORS (PLEASE SEE 06E076). DOMETIC WILL REPAIR THESE REFRIGERATORS BY INSTALLING A SECONDARY BURN HOUSING, A THERMAL FUSE, AND A MELT FUSE FREE OF CHARGE. DOMETIC HAS RETAINED STERICYCLE INC. TO MANAGE THIS CAMPAIGN. STERICYCLE WILL…
Complaints by component
STRUCTURE
1
Total complaints1
What owners report
Verbatim reports filed with NHTSA, lightly edited for readability and with personal
information removed.
“The coach's storage door leaked which caused the wiring, fuses and 2000 amp inverter to get wet. This resulted in shorts and electrical failures. *nm the electrical failure included the windshield wipers, turn signal, dash gauges, headlight and taillights (2002 tiffin zephyr). *nm”