THE IGNITION SWITCH COULD EXPERIENCE AN INTERNAL SHORT CIRCUIT.
THIS CONDITION COULD CAUSE OVERHEATING, SMOKE, AND POSSIBLY FIRE IN THE STEERING COLUMN AREA OF THE VEHICLE.
DEALERS WILL REPLACE THE IGNITION SWITCH.
The 1990 Ford F-150 has 4 NHTSA recall campaigns affecting an estimated 9,143,100 vehicles. Recall repairs are always free at any authorized dealer. Owners have filed 315 complaints with NHTSA, most often about the fuel system, gasoline. Last updated July 5, 2026.
THE IGNITION SWITCH COULD EXPERIENCE AN INTERNAL SHORT CIRCUIT.
THIS CONDITION COULD CAUSE OVERHEATING, SMOKE, AND POSSIBLY FIRE IN THE STEERING COLUMN AREA OF THE VEHICLE.
DEALERS WILL REPLACE THE IGNITION SWITCH.
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.
SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.
REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.
UNDER CERTAIN CONDITIONS, THE SNAP RING THAT LOCATES THE PARK GEAR ON THE OUTPUT SHAFT OF THE TRANSMISSION MAY FRACTURE.
WHEN THE GEAR IS PLACED IN PARK, THE PARK GEAR WOULD NOTENGAGE, ALLOWING THE TRUCK TO ROLL FREELY IF THE PARKING BRAKE IS NOT PROPERLYSET. THIS COULD RESULT IN AN ACCIDENT.
INSTALL IMPROVED SNAP RING AND REVISED TRANSMISSION EXTENSION HOUSING.
INCORRECTLY INSTALLED FUEL LINE CONNECTORS HAVE FUEL SUPPLY AND RETURN LINES CROSSED.
FUEL COULD BE TRANSFERRED FROM ONE TANK TO THE OTHER,POSSIBLY RESULTING IN FUEL OVERFLOW AND SPILLAGE, IN PRESENCE OF AN IGNITIONSOURCE, A FIRE COULD OCCUR.
REPLACE FUEL LINE ASSEMBLY.
Verbatim reports filed with NHTSA, lightly edited for readability and with personal information removed.
“Unknown component(s) failure causes vehicle to stall at speed that vary, fuel supply is sufficient and battery good, no indication that stall is imminent. Varying time lapses allow restart and normal driving. Ammeter and temp gauges normal. Re-start may occur immediately or several hours. Online…”
“Replace front fuel pump, and have been using that tank exclusively as it starts and runs better than the rear. This morning I noticed fuel leaking from the rear tank, which was half full when I started using the front tank. I opened the filler neck and gas was spilling out. I turned the key to…”
“Tl* the contact owns a 1990 ford f-150. The contact stated fuel leaked from one tank into the other tank and caused the vehicle to jerk without warning. The contact pulled over to the side of the roadway and switched the fuel button to the other tank. The vehicle was towed to the residence. The…”
“Tl* the contact owns a 1990 ford f-150. The contact noticed a strong fuel odor outside the vehicle and inside while driving various speeds. Also, while examining the vehicle and opening the fuel tank, the fuel poured out. Quirk ford of augusta (7 water st, hallowell, me 04347, [REDACTED]) was…”
“Tl* the contact owns a 1990 ford f-150. The contact stated that the gear shifted out of the park position intermittently while parked on an incline. Whenever the vehicle shifted out of gear, it rolled forward until the emergency brake was engaged. The vehicle stopped moving when it rolled into a…”
“Tl* the contact owns a 1990 ford f-150. While filling up the front fuel tank, the contact stated that the fuel from the front entered the rear fuel tank, which caused the rear fuel tank to overflow. The dealer (baxtor ford south, 9203 s 145th st, omaha, ne 68318) stated that there was no recall on…”
“Tl* the contact owns a 1990 ford f-150. The contact stated that while in reverse, the fuel was leaking excessively. The vehicle was taken to an independent mechanic where it was diagnosed that the crossover valve needed to be replaced. The vehicle was not repaired. The vin was not included in…”
“I had filled my truck up and fuel started to pour out from somewhere out of the gas tank I didn't know what was going on I stop this guy & he had a jug he caught some of the gas I was hoping didn't no one throw a cig. Cause we would have been threw this was march 14, 2015 & it also happened in…”
There is no summary currently available
===
There is no summary currently available
There is no summary currently available
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO…
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO…
SEE CLOSE RESUME
There is no summary currently available
There is no summary currently available
There is no summary currently available
There is no summary currently available
THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS…
Recall, complaint, and investigation records from official NHTSA datasets (FLAT_RCL, FLAT_CMPL, FLAT_INV), synced weekly. Counts reflect NHTSA records for the 1990 Ford F-150 as of July 5, 2026. Complaint narratives are consumer-submitted and unverified. This page contains ads and affiliate links. Full methodology.