1999 Ford E-350 Recalls

Recalls on record Updated July 2026

The 1999 Ford E-350 has 8 NHTSA recall campaigns affecting an estimated 8,487,043 vehicles. Recall repairs are always free at any authorized dealer. Owners have filed 77 complaints with NHTSA, most often about the tires. Last updated July 5, 2026.

Recall campaigns

VEHICLE SPEED CONTROL 09V399000 2009-10-13 4,500,000 affected
Defect

FORD IS RECALLING MODEL YEARS 1995-2003 WINDSTAR, 2000-2003 EXCURSION DIESEL, 1993-1997 AND 1999-2003 F-250 SD THROUGH F-550 SD DIESEL, 1992-2003 E-150 THROUGH E-550, 1995-2002 EXPLORER, 1997 AND 2002 MERCURY MOUNTAINEER, 1995-1997 AND 2001-2003 RANGER, AND 1994 F53 VEHICLES EQUIPPED WITH THE TEXAS INSTRUMENTS SPEED…

Consequence

A VEHICLE FIRE COULD OCCUR WITH OR WITHOUT THE ENGINE RUNNING.

Remedy

FORD WILL NOTIFY OWNERS THAT DEALERS WILL INSTALL A FUSED WIRING HARNESS IN LINE WITH THE SCDS. ON 1999-2003 WINDSTAR VEHICLES WITH A LEAKING SCDS, DEALERS WILL ALSO INSPECT THE ABS CONTROL MODULE CONNECTOR AND REPAIR AS NECESSARY. REPAIRS WILL BE COMPLETED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON OCTOBER 27,…

VEHICLE SPEED CONTROL 08V051000 2008-02-04 225,000 affected
Defect

FORD IS RECALLING 225,000 MY 1992-2003 ECONOLINE, MY 1993-1995 TAURUS SHO, MY 1992-1998 CROWN VICTORIA, MY 1993 BRONCO, F-SERIES, MY 1995-1997 F-SERIES SUPER DUTY STRIPPED CHASSIS, MY 1992-1998 MERCURY GRAND MARQUIS, AND MY 1992-1995 LINCOLN TOWN CAR VEHICLES. THE AFFECTED VEHICLES WERE PREVIOUSLY REPAIRED USING A…

Consequence

AS A RESULT, THE FUSE IS LOCATED IN THE OUTPUT CIRCUIT RATHER THAN IN THE INTENDED INPUT POWER FEED CIRCUIT, AND MAY NOT OFFER THE INTENDED PROTECTION IN THE EVENT OF AN ELECTRICAL SHORT TO GROUND.

Remedy

DEALERS WILL INSTALL A NEW WIRING HARNESS, OR REPLACE THE MATING ELECTRICAL COMPONENT. THE RECALL BEGAN ON FEBRUARY 18, 2008. OWNERS MAY CONTACT FORD AT 1-800-392-3673.

VEHICLE SPEED CONTROL 07V336000 2007-08-03 3,600,000 affected
Defect

ON CERTAIN PICKUP TRUCKS, PASSENGER VEHICLES, SPORT UTILITY VEHICLES, AND MOTOR HOMES CHASSIS, THE SPEED CONTROL DEACTIVATION SWITCH MAY, UNDER CERTAIN CONDITIONS, LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.

Consequence

THIS COULD RESULT IN AN UNDERHOOD FIRE.

Remedy

DEALERS WILL INSTALL A FUSED WIRING HARNESS. OWNERS OF THE PASSENGER CARS INCLUDED IN THIS CAMPAIGN WILL BE INSTRUCTED TO RETURN THEIR VEHICLES TO THEIR DEALERS TO HAVE THE SPEED CONTROL DEACTIVATION SWITCH DISCONNECTED AS AN INTERIM REPAIR. AS SOON AS REPAIR PARTS ARE AVAILABLE (EXPECTED OCTOBER 2007), OWNERS WILL…

FUEL SYSTEM, GASOLINE 01V114000 2001-04-05 151,000 affected
Defect

VEHICLE DESCRIPTION: ON CERTAIN VANS WITH AMBULANCE PREP PACKAGES OR OTHER SEVERE-DUTY APPLICATIONS INVOLVING OPERATION AT OR NEAR THE GROSS VEHICLE WEIGHT WITH FREQUENT TWISTING OF THE VEHICLE BODY, SUCH AS OFF-ROAD, ROUGH ROAD OR SPEED BUMP EVENTS, THE 35 GALLON MID-SHIP FUEL TANK COULD DEVELOP A CRACK WHERE IT…

Consequence

FUEL LEAKAGE IN THE PRESENCE OF AN IGNITION SOURCE COULD RESULT IN A FIRE.

Remedy

DEALERS WILL INSPECT THE FUEL TANK AND, IF CRACKED, WILL REPLACE THE TANK. INSULATOR PADS WILL BE INSTALLED ON ALL VEHICLES TO REDUCE THE STRESS LEVELS IN THE FUEL TANK. OWNER NOTIFICATION BEGAN APRIL 19, 2001. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE…

EQUIPMENT 00V284000 2000-09-21 4,500 affected
Defect

VEHICLE DESCRIPTION: BI-FUEL CNG PICKUP TRUCKS AND BI-FUEL CNG VANS, MODIFIED BY CFI CONTROL SYSTEMS, INC., FAIL TO CONFORM TO THE REQUIREMENTS OF FMVSS NO. 303, "FUEL SYSTEM INTEGRITY OF COMPRESSED NATURAL GAS VEHICLES." THE LABEL AFFIXED TO THE FUEL FILLER DOOR BY THE VEHICLE MODIFIER CONTAINS THE INSPECTION DATE…

Consequence

THESE VEHICLES DO NOT COMPLY WITH THE REQUIREMENTS.

Remedy

OWNERS WILL BE PROVIDED A LABEL WITH THE REQUIRED STATEMENT, ALONG WITH INSTRUCTIONS FOR AFFIXING THE LABEL AT THE FUEL FILLER DOOR. OWNER NOTIFICATION BEGAN NOVEMBER 2, 2000. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE…

WHEELS 00V115000 2000-04-19 3,300 affected
Defect

VEHICLE DESCRIPTION: CUTAWAYS AND STRIPPED CHASSIS WITH SINGLE REAR WHEELS. THE LUG NUTS CAN POTENTIALLY BOTTOM OUT ON A SHOULDER ON THE STUDS.

Consequence

IF THIS OCCURS, THERE CAN BE AN INADEQUATE CLAMP LOAD TO ATTACH THE WHEEL TO THE AXLE, RESULTING IN NOISE, DAMAGE TO THE WHEEL AND HUB, OR IN EXTREME CASES, LOSS OF A REAR WHEEL WHILE THE VEHICLE IS BEING DRIVEN.

Remedy

DEALERS WILL REPLACE THE REAR WHEEL ATTACHING STUDS.

LATCHES/LOCKS/LINKAGES 99V046000 1999-03-15 2,893 affected
Defect

VEHICLE DESCRIPTION: UTILITY VANS EQUIPPED WITH THE "60/40" HINGED SIDE CARGO DOORS. THE STRIKERS FOR THE 60/40 DOOR SINGLE LATCH SYSTEM WERE FOUND TO CONTAIN STRESS CRACKS AT THE STRIKER WIRE LOWER STAKE JOINT. STRIKERS WITH STRESS CRACKS MAY NOT MEET THE REQUIREMENTS OF FMVSS NO. 206, "DOOR LOCKS AND DOOR…

Consequence

IN THE EVENT OF A CRASH, THE DOOR STRIKERS MAY NOT HOLD THE DOOR, INCREASING THE RISK OF PERSONAL INJURY OR PROPERTY DAMAGE.

Remedy

DEALERS WILL REPLACE THE DOOR STRIKER.

POWER TRAIN 98V257000 1998-10-14 350 affected
Defect

VEHICLE DESCRIPTION: PICKUP TRUCKS BUILT WITH SINGLE REAR WHEELS AND EQUIPPED WITH 3.55:1 AND 3.73:1 AXLE RATIO. THESE VEHICLES WERE BUILT WITH INCORRECT SPEEDOMETER DRIVEN GEARS, RESULTING IN A LOWER SPEEDOMETER READING THAN THE ACTUAL VEHICLE SPEED BEING DRIVEN.

Consequence

THIS CAN RESULT IN THE VEHICLE BEING DRIVEN AT AN UNSAFE OR ILLEGAL SPEED SHOULD THE DRIVER NOT REALIZE THAT HIS VEHICLE ROAD SPEED IS GREATER THAN THE SPEEDOMETER INDICATION.

Remedy

DEALERS WILL INSTALL THE CORRECT SPEEDOMETER GEAR.

Complaints by component

TIRES
14
TIRES:TREAD/BELT
8
1crashes4injuries1deaths
ENGINE AND ENGINE COOLING:ENGINE
5
1fires
ENGINE AND ENGINE COOLING
4
1fires
ELECTRICAL SYSTEM
3
1fires
ENGINE AND ENGINE COOLING:ENGINE:GASOLINE
3
FUEL/PROPULSION SYSTEM
3
AIR BAGS:FRONTAL
2
1crashes2injuries
FUEL SYSTEM, GASOLINE
2
1fires
SERVICE BRAKES, HYDRAULIC:ANTILOCK/TRACTION CONTROL/ELECTRONIC LIMITED SLIP
2
Total complaints77

What owners report

Verbatim reports filed with NHTSA, lightly edited for readability and with personal information removed.

“The contact owns a 1999 ford e-350 jamboree equipped with sailun tires, tire line: terramax h/t, tire size: 225/75/r16, dot number: (535ple50). The contact stated that while driving approximately 55 mph, there were pieces of the driver's side inside dual tire striking the underside of the vehicle…”

TIRES:TREAD/BELT · reported 2022-08-31

“I recently purchased a used 24' 1999 winnebago itasca spirit with very low mileage and at that time I noticed a shaking or vibration problem possibly coming from the tires. I owned a motor home in the past and have some experience. This motor home sat for several years so I attributed the shaking…”

STEERING · reported 2019-10-07

“I recently purchased a used 24' 1999 winnebago itasca spirit with very low mileage and at that time I noticed a shaking or vibration problem possibly coming from the tires. I owned a motor home in the past and have some experience. This motor home sat for several years so I attributed the shaking…”

WHEELS · reported 2019-10-07

“I was in an accident and my air bags did not work I have damage to front end and rear end”

AIR BAGS · reported 2017-04-15

“Tl* the contact owns a 1999 ford e-350 equipped with nexen tires, tire line: roadian ht, tire size: lt225/ 75r16 (n/a), and dot number: beakbamr3312. The contact stated that while driving at various speeds, the steering wheel started violently shaking without warning. The vehicle was taken to an…”

TIRES · reported 2015-10-12

“The vehicle stalls on numerous occasions due to lack of fuel. Investigation proved that the interior paint of the gas tank peals blocking the fuel pump. Research shows that delamination of the gas tank is frequent in this model causing a very unsafe condition as the van can stop at anytime as it…”

FUEL/PROPULSION SYSTEM · reported 2014-01-24

“Tl* the contact owns a 1999 ford f350. The contact stated that while driving 60 mph, the contact noticed that the fuel tank was dangling from the vehicle. The vehicle was taken to an independent mechanic for diagnosis where it was stated that the fuel tank support straps were rusted. The vehicle…”

FUEL/PROPULSION SYSTEM · reported 2013-06-15

“Tl* the contact owns a 1999 ford e-350 equipped with unicorn creation lt tires, line size 225/75/r16. The contact stated that she heard a loud noise outside the vehicle and noticed that the passenger side rear outer tire blew out. The tire was taken to a tire shop and they stated that the steel…”

TIRES · reported 2012-08-24

Defect investigations

Investigation DP05005 Opened 2005-09-22 · closed 2006-01-04

SPARK PLUG EJECTION FROM CYLINDER HEAD

ON SEPTEMBER 6, 2005, ODI RECEIVED A PETITION REQUESTING THAT THE AGENCY INVESTIGATE ALLEGATIONS OF ENGINE SPARK PLUG EJECTION IN CERTAIN MODEL YEAR 1997 THROUGH 2004 FORD VEHICLES WITH TRITON V-8 AND V-10 ENGINES.ODI RECEIVED A TOTAL OF 474 NON-DUPLICATIVE COMPLAINTS ON THE SUBJECT VEHICLES WHERE THE COMPLAINANT, OR…

Investigation DP05005 Opened 2005-09-22 · closed 2006-01-04

SPARK PLUG EJECTION FROM CYLINDER HEAD

ON SEPTEMBER 6, 2005, ODI RECEIVED A PETITION REQUESTING THAT THE AGENCY INVESTIGATE ALLEGATIONS OF ENGINE SPARK PLUG EJECTION IN CERTAIN MODEL YEAR 1997 THROUGH 2004 FORD VEHICLES WITH TRITON V-8 AND V-10 ENGINES.ODI RECEIVED A TOTAL OF 474 NON-DUPLICATIVE COMPLAINTS ON THE SUBJECT VEHICLES WHERE THE COMPLAINANT, OR…

Investigation DP05005 Opened 2005-09-22 · closed 2006-01-04

SPARK PLUG EJECTION FROM CYLINDER HEAD

ON SEPTEMBER 6, 2005, ODI RECEIVED A PETITION REQUESTING THAT THE AGENCY INVESTIGATE ALLEGATIONS OF ENGINE SPARK PLUG EJECTION IN CERTAIN MODEL YEAR 1997 THROUGH 2004 FORD VEHICLES WITH TRITON V-8 AND V-10 ENGINES.ODI RECEIVED A TOTAL OF 474 NON-DUPLICATIVE COMPLAINTS ON THE SUBJECT VEHICLES WHERE THE COMPLAINANT, OR…

Investigation EA02018 Opened 2002-08-19 · closed 2003-08-22

RAPID TIRE DEFLATION

THIS INVESTIGATION WAS OPENED ON CERTAIN FORD PICKUP TRUCKS AND VANS TO EVALUATE THE EFFECTS OF A VALVE STEM EJECTION (WITH RAPID AIR LOSS) AND A SLOW LEAKING VALVE STEM ON VEHICLE HANDING.DURING THE INVESTIGATION, ODI EVALUATED OVER 1,100 COMPLAINTS AND WARRANTY CLAIMS, CONDUCTED VEHICLE DYNAMIC TESTING ON A SUBJECT…

Investigation EA02018 Opened 2002-08-19 · closed 2003-08-22

RAPID TIRE DEFLATION

THIS INVESTIGATION WAS OPENED ON CERTAIN FORD PICKUP TRUCKS AND VANS TO EVALUATE THE EFFECTS OF A VALVE STEM EJECTION (WITH RAPID AIR LOSS) AND A SLOW LEAKING VALVE STEM ON VEHICLE HANDING.DURING THE INVESTIGATION, ODI EVALUATED OVER 1,100 COMPLAINTS AND WARRANTY CLAIMS, CONDUCTED VEHICLE DYNAMIC TESTING ON A SUBJECT…

Investigation EA10003 Opened 2010-04-13 · closed 2012-03-05

HVAC Switch Failures

This investigation was opened based on one complaint and reports from four transportation fleets alleging 182 blower motor control switch failures.ODI was concerned that these melting and burning switches could lead to an open flame that could spread throughout the vehicle.After a comprehensive review of all data…

Investigation PE09055 Opened 2009-12-07 · closed 2010-04-21

HVAC Switch Failures

ODI has received 1 complaint and reports from 4 transportation fleets alleging 182 switch failures.Each fleet operates mini buses built on a Ford E350 or E450 cutaway chassis.The OEM HVAC blower switches have melted, smoked, burned or experienced open flame and become inoperable on vehicles in each fleet.Some drivers…

Investigation PE99047 Opened 1999-07-12 · closed 1999-09-23

BLOW BACK DURING REFUELING

There is no summary currently available

Sources & methodology

Recall, complaint, and investigation records from official NHTSA datasets (FLAT_RCL, FLAT_CMPL, FLAT_INV), synced weekly. Counts reflect NHTSA records for the 1999 Ford E-350 as of July 5, 2026. Complaint narratives are consumer-submitted and unverified. This page contains ads and affiliate links. Full methodology.