2000 Altec Lr Series Aerial Device Recalls

Recalls on record Updated July 2026

The 2000 Altec Lr Series Aerial Device has 1 NHTSA recall campaign affecting an estimated 3,824 vehicles. Recall repairs are always free at any authorized dealer. Last updated July 5, 2026.

Recall campaigns

EQUIPMENT 23V433000 2023-06-16 3,824 affected
Defect

Altec Industries, Inc. (Altec) is recalling certain 1999-2022 L Series and LR Series aerial devices. A hydraulic hose may have been installed between the cylinder port and load-holding valve instead of metallic tubing, which can result in a damaged hydraulic hose and failure of the load-holding feature.

Consequence

Failure of the load-holding feature can result in unintended movement of the platform or load, increasing the risk of injury.

Remedy

Altec will inspect the units for a hydraulic hose and replace it with specified metallic tubing, as necessary, free of charge. Owner notification letters are expected to be mailed August 11, 2023. Owners may contact Altec customer service 1-877-462-5832. Altec's number for this recall is CSN 3090.

Sources & methodology

Recall, complaint, and investigation records from official NHTSA datasets (FLAT_RCL, FLAT_CMPL, FLAT_INV), synced weekly. Counts reflect NHTSA records for the 2000 Altec Lr Series Aerial Device as of July 5, 2026. Complaint narratives are consumer-submitted and unverified. This page contains ads and affiliate links. Full methodology.